Blatteau3

In-water recompression breathing oxygen reduced venous bubbles when compared to normobaric oxygen

Clinical bottom line:

Venous bubble severity grade after a provocative dive were reduced when divers received in-water oxygen compared to normobaric oxygen

Citation/s:1. Blatteau J-E, Pontier J-M. Effect of in-water recompression with oxygen to 6 msw versus normobaric oxygen breathing on bubble formation in divers. Eur J Appl Physiol. 2009;106:691-5.
Lead author's name and fax: Jean-Eric Blatteau, je.blatteau@infonie.fr

Three-part Clinical Question:Following a dive breathing air at 30msw (400 kPa) for 30minutes, does a period breathing normobaric oxygen (100kPa), compared to breathing oxygen in-water at 6msw (160 kPa), result in decreased grade scores for venous gas bubbles?
Search Terms: Diving; Decompression sickness; Bubble; In-water recompression

The Study:
Single-blinded randomised controlled trial with intention-to-treat.
The Study Patients: Healthy adult military divers.
Control group (N = 19 ; 19 analysed): Single dive to 30 msw for 30 minutes breathing air on open-circuit scuba followed at 10 minutes after surfacing by a period of 30 minutes of normobaric oxygen at 15 l/min. Doppler was performed at 40, 60 and 80 minutes after surfacing.
Experimental group (N = 19 ; 19 analysed): As above, but given 30 minutes of oxygen breathing at 6 msw (in-water recompression) after surfacing.

The Evidence

Non-event Outcome Time to outcome Normobaric Oxygen In-water Oxygen Median difference, 95%CI and P-value
Kissman Integrated Severity Score (KISS). Median and IQR Integrated (40, 60 and 80 minutes)

1.6

(0 to 12.5)

0

(0 to 0.39)

1.2 (0 to 10.9)

P = 0.003

 

Comments: 
1. There is no description of the in-water recompression procedure including oxygen delivery system or diver support system.
2. There is no description of the normobaric oxygen delivery mask. Was the optimum delivery system used?
3. The participants were all military divers with sex not given.
4. There was no sample size calculation or power analysis.
5. Incorrect statistical tests seem to have been used for analysis. KISS integrates bubble grades over time and should be analysed with a non-parametric approach.
6. Tables and figures not referred to in manuscript text. Raw data was provided. 7. Analysis provided in this CAT was done using the Mann-Whitney U test and performed by the CAT authors.

 

Appraised by: Denise F Blake and Mike Bennett; Saturday, 25 May 2019
Email: denise.blake@health.qld.gov.auSS control and HOB

Kill or Update By: January 2021

 

Sumhorsa.gif

 

BACK