Risberg

No reduction in detectable venous bubbles in volunteer hyperbaric attendants with nitrox breathing or increased 100% oxygen breathing periods.

Clinical bottom line:

1. There were no important differences in the grade or frequency of venous bubbles detected between the three arms of the study.
2. There was no measured advantage to any of the three experimental profiles.

Citation/s: 1. Risberg J, Englund M, Aanderud L, Eftedal O, Flook V, Thorsen E. Venous gas embolism in chamber attendants after hyperbaric exposure. Undersea and Hyperbaric Medicine 2004;31(4):417-429.

Lead author's name and fax: Jan Risberg no contact given

Three-part Clinical Question:For attendants during hyperbaric oxygen treatment sessions, does modification of the breathing gas, compared to air breathing, reduce the degree of venous bubbling associated?

Search Terms: Doppler bubble detection; decompression stress; occupational diving

​​​​​​​The Study: Double-blinded concealed randomised controlled trial with intention-to-treat.

The Study Patients: Volunteer females employed at the participating centres. Volunteers acted as their own controls.

Control group (N = 9; 9 analysed): Compression to 2.4 ATA over 15 minutes, followed by 95 minutes breathing air, then five minutes on 100% oxygen before decompression on 100% oxygen over seven minutes (routine group).

Experimental group (N = 10; 10 analysed): Two experimental groups. The same profile but with 10 minutes on 100% oxygen at 2.4 ATA and during the decompression over 14 minutes (revised group); and a third group that breathed 40.5% oxygen for three 30 minute periods at 2.4 ATA, but no 100% oxygen periods (Nitrox group).

​​​​​​​The Evidence:

Outcome

Time to Outcome

Control group

Combined experimental groups

Relative risk reduction

Absolute risk reduction

NNT

VGE present after exposure (proportion)

15 minutes

0.67

0.80

-20%

-0.13

-8

     

95% CIs:

-79% to 39%

-0.53 to 0.26

NNT 4 to INF; NNH 2 to INF

 

​​​​​​​Comments:

1. Very small study of only 10 subjects.

2. The usefulness of using VGE detection to quantify decompression stress in this population is unclear.

3. Using a mathematical model, the authors calculated that the routine, revised and nitrox series would release 2.1, 1.3 and 1.6 µl gas/ml blood into the bubbles in the central venous blood.

4. The authors switched to monoplace chambers for routine treatment following this investigation

Appraised by: Mike Bennett m.bennett@unsw.edu.au; Tuesday, 6 December 2016

Kill or Update By: December 2021

 